Welcome to Changzhou Shuangzhen Electromechanical Co., Ltd.!
Self-cleaning Air Compressor Inlet Filter

Self-cleaning Air Compressor Inlet Filter

Inlet pressure 0.6–0.85 MPa
Outlet dew point 2–10 °C (atmospheric)
Air flow 1.2–100 m³/min
Cooling method Blower purge
Inlet temperature ≤ 45 °C
Pressure drop ≤ 0.02 MPa
Installation Unit base frame, no foundation required

Specifications

The blower-purge adsorption dryer draws ambient air via a blower, heats it for desiccant regeneration, and consumes no product compressed air — ideal for energy-saving retrofits of large-flow systems.

← Previous:Blower Purge Desiccant Dryer Next →